This set of Electrical engineering Multiple Choice Questions & Answers (MCQs) focuses on study of “ Power Generation ”. These questions are chosen from a collection of most authoritative and best reference books on Electrical engineering. Our aim is to prepare an individual for competitive exams like NTS, GAT, ECAT, University and College entrance exams, Jobs and interviews. One should practice our MCQS to assimilate Power Generation comprehensively.
17. Demand factor is defined as___________?
Average load/maximum load.
Maximum demand/connected load
Connected load/maximum demand.
Average load x maximum load
Answer & Solution
No Solution for this Answer..! Report or Discus this Question
18. In thermal power plant, heat from the flue gases is utilized in___________?
Super heater
Condenser
Economizer
Chimney
Answer & Solution
No Solution for this Answer..! Report or Discus this Question
19. Which of the following power plant has highest Depreciation charges?
Thermal plant
Diesel plant
Hydroelectric plant
All have same
Answer & Solution
No Solution for this Answer..! Report or Discus this Question
20. Which of the following power plant has least fuel transportation______________?
Nuclear power plants
Diesel generating plants
Thermal power plants
Steam power stations
Answer & Solution
No Solution for this Answer..! Report or Discus this Question
21. Annual operating expenditure of a power plant consists of_________?
Fixed charges
Semi-fixed charges
Running charges
All of the above
Answer & Solution
No Solution for this Answer..! Report or Discus this Question
22. Which of the following load is responsible for lower power factor of supply system__________?
Induction motors
Resistive loads
Synchronous Motors
All of the above
Answer & Solution
No Solution for this Answer..! Report or Discus this Question
23. Load factor of a power station is defined as____________?
Maximum demand/average load
Average load x maximum demand
Average load/maximum demand
None of the above
Answer & Solution
No Solution for this Answer..! Report or Discus this Question
24. Load curve is useful in deciding the__________?
A. operating schedule of generating units
Sizes of generating units
Total installed capacity of the plant
All of the above
Answer & Solution
No Solution for this Answer..! Report or Discus this Question
25. One kilowatt hour is equal to_________?
532 k cal.
735 k cal.
746 k cal.
860 k cal.
Answer & Solution
No Solution for this Answer..! Report or Discus this Question
26. If the load factor of a power station is high then its cost of generation will be_______?
High.
Low.
Remain same.
Depend upon plant type.
27. At low value of power factor, the cost of generation of a power station will be____________?
High
Low
Remain same
None of the above
28. Compounding of steam turbine is done for_______________?
Reducing the work done
Increasing the rotor speed
Reducing the rotor speed
Balancing the turbine
Answer & Solution
No Solution for this Answer..! Report or Discus this Question
29. The value of the reheat factor is of the order of_____________?
0.8 to 1.0
1.0 to 1.05
1.1 to 1.5
Above 1.5
Answer & Solution
No Solution for this Answer..! Report or Discus this Question
30. Reheat factor is the ratio of_____________?
Isentropic heat drop to useful heat drop
Adiabatic heat drop to isentropic heat drop
Cumulative actual enthalpy drop for the stages to total is isentropic enthalpy heat drop
Answer & Solution
No Solution for this Answer..! Report or Discus this Question